software: x-act

From the setup of the system to the CT scan’s 3D rendering, everything is combined in a single software suite called X-Act.

rx solutions
X-Act software

X-Act

RX Solutions X-Act software integrates a complete interface to inspect accurately your samples. This is not only an acquisition and reconstruction software, it is above all an advanced solution that embeds a large number of functionalities that always enable to get the best possible results, whatever the sample.

Key Features


  • - Easy and intuitive interface
    - Multiple acquisitions modes : Conventional, helical, laminography, shift & stack modes
    - Programmable automatic calibration and stabilization
    - Automated wizard enabling non expert users to run CT scans
    - Real time artefacts corrections: focal spot drift, ring artefacts, beam hardening, phase contrast...


X-Act : A powerful x-ray software
radiography, acquisition & reconstruction

Radiography

Live inspection


Radiography is quick and easy with X-Act. Software filters are included to improve sharpness and contrast.  3D measurements can be taken directly on the  radio.

 

Acquisition

Data acquisition

 

The workpiece previously positioned in the equipment rotates through 360°. During this rotation, a set of radio projections are acquired at different angles.

 

Reconstruction

Data processing

 

All the projections made during the acquisition step are reconstructed as a 3D volume. The volume thus generated will serve as the basis for the optional third step: post-processing.


X-Act Ct Art :
Advanced Artefacts Reconstruction

Phase Contrast Removal

 

High resolution in X-Ray µCT generally means the occurrence of small angle scattering also known as phase contrast artefacts, especially with low absorbing materials. Phase signal contributions are no longer negligible regarding the X-Ray absorption, resulting in a new contrast phenomena that offers edges enhancements, but a lower absorption contrast between phases.

 

Beam Hardening Correction

This correction allows you remove beam artefacts from your component without having a proper spectrum estimation. It's a user-guided algorithm offering a simple way to compute the estimated absorption photons curve and correct the image deviation.

 

Ring Artefact Removal

 

Ring artefacts result from a non-linear response of the detector which generates circular artefacts centered on the rotation axis. This correction works directly on the projections and preserves the image features/resolution.

 